New VSA

classic Classic list List threaded Threaded
3 messages Options
| Threaded
Open this post in threaded view
|

New VSA

Miguel Barrera
Hi,
I need to use some bandwidth control parameters for Huawei Cloud Campus
Agile Controller (HW-Input-Committed-Information-Rate;
HW-Output-Committed-Information-Rate) but I haven't been able to make it
work.

On my dictionary file I set them like this, and RADIUS does not start
ATTRIBUTE       HW-Input-Committed-Information-Rate     26.2    integer
ATTRIBUTE       HW-Output-Committed-Information-Rate    26.5    integer

And when I use other id like this
ATTRIBUTE       HW-Input-Committed-Information-Rate     62    integer
ATTRIBUTE       HW-Output-Committed-Information-Rate    63    integer
My radtest is accurate
Received Access-Accept Id 153 from 3.92.114.166:1812 to 0.0.0.0:0 length 62
        Session-Timeout = 1800
        HW-Input-Committed-Information-Rate = 1200000
        HW-Output-Committed-Information-Rate = 1200000

But the Attribute Value Pair on a .pcap are not
[image: image.png]

How should I handle these parameters?

I know the vendor id is 2011 and the VSA are established as 26.2 and 26.5
bit I dont know how to implement them.

Thank you so much.
Gracias, quedo atento.

-
List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html

image.png (57K) Download Attachment
| Threaded
Open this post in threaded view
|

Re: New VSA

Alan DeKok-2
On Jun 23, 2020, at 3:07 PM, Miguel Barrera <[hidden email]> wrote:

>
> Hi,
> I need to use some bandwidth control parameters for Huawei Cloud Campus
> Agile Controller (HW-Input-Committed-Information-Rate;
> HW-Output-Committed-Information-Rate) but I haven't been able to make it
> work.
>
> On my dictionary file I set them like this, and RADIUS does not start
> ATTRIBUTE       HW-Input-Committed-Information-Rate     26.2    integer
> ATTRIBUTE       HW-Output-Committed-Information-Rate    26.5    integer

  Yes, because that isn't correct.

> And when I use other id like this
> ATTRIBUTE       HW-Input-Committed-Information-Rate     62    integer
> ATTRIBUTE       HW-Output-Committed-Information-Rate    63    integer

  You can't just invent numbers and have it work.

  From the pcap output, it looks like you just edited the main dictionary.  That's wrong.

  The attributes you're looking for are already defined in dictionary.huawei.  Just use the names given there.  It will work.

> I know the vendor id is 2011 and the VSA are established as 26.2 and 26.5
> bit I dont know how to implement them.

  Read dictionary.huawei, and use the names given for attributes "2" and "5".

  Alan DeKok.


-
List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html
| Threaded
Open this post in threaded view
|

Re: New VSA

Jorge Pereira-2
In reply to this post by Miguel Barrera
Hi Miguel,

After a quick Google, I found that
https://support.huawei.com/enterprise/en/doc/EDOC1100055131/6a2e56b2/description-of-radius-attributes 
describing those attributes for Huawei. Therefore, I've noticed that we
already have such a dictionary in our code, but slight differences in
the prefix. e.g:
https://github.com/FreeRADIUS/freeradius-server/blob/v3.0.x/share/dictionary.huawei

Take a look at dictionary.huawei in your system (e.g: find / -name
dictionary.huawei ) and you will see that just need to use the existing
attributes.

e.g: second column are the exiting attributes in dictionary.huawei

HW-Input-Committed-Burst-SizeĀ  -> Huawei-Input-Burst-Size
HW-Output-Committed-Information-Rate -> Huawei-Output-Average-Rate

Btw, I didn't find any reference for VSA in the Huawei link, and not
even in our dictionary. Indeed, it looks like the customer launched a
new NAS product and renamed all existing attributes.

On 23/06/2020 16:07, Miguel Barrera wrote:

> Hi,
> I need to use some bandwidth control parameters for Huawei Cloud Campus
> Agile Controller (HW-Input-Committed-Information-Rate;
> HW-Output-Committed-Information-Rate) but I haven't been able to make it
> work.
>
> On my dictionary file I set them like this, and RADIUS does not start
> ATTRIBUTE       HW-Input-Committed-Information-Rate     26.2    integer
> ATTRIBUTE       HW-Output-Committed-Information-Rate    26.5    integer
>
> And when I use other id like this
> ATTRIBUTE       HW-Input-Committed-Information-Rate     62    integer
> ATTRIBUTE       HW-Output-Committed-Information-Rate    63    integer
> My radtest is accurate
> Received Access-Accept Id 153 from 3.92.114.166:1812 to 0.0.0.0:0 length 62
>          Session-Timeout = 1800
>          HW-Input-Committed-Information-Rate = 1200000
>          HW-Output-Committed-Information-Rate = 1200000
>
> But the Attribute Value Pair on a .pcap are not
> [image: image.png]
>
> How should I handle these parameters?
>
> I know the vendor id is 2011 and the VSA are established as 26.2 and 26.5
> bit I dont know how to implement them.
>
> Thank you so much.
> Gracias, quedo atento.
>
>
> -
> List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html
-
List info/subscribe/unsubscribe? See http://www.freeradius.org/list/users.html